Table of Contents
INTRODUCTION: Welcome ...............i
About Your Documentation .............i
Conventions .....................i
OIT Models Supported .................ii
Operational Overview .................ii
CHAPTER 1: Getting Started...............1
What You Will Need ..................1
Installing STEPware-100 ...............1
STEPware-100 Tutorial.................2
Create a Basic STEPware-100 Project . . . 2
Add Two Predefined Messages ........3
Configure a Push-on/Push-off Function Key 4
Configure a Momentary Function Key. . . 7
Configure a Shifted Function Key ......7
Configure a SHIFT Function Key .......8
Downloading a STEPware-100 Project .....9
Connect OIT to PC and Power Supply. . . 9
Place OIT in Download/Upload Mode . . 10
Transfer Project ...................11
Verifying Your OIT is Operational.........13
Connect OIT to PC and Power Supply. . . 13
Setup PC’s Terminal Emulation Program. 14
Sample Communications Session ......14
Connecting Your OIT to the Host Controller . 15
RS-232 (Interactive & Block modes) ....15
RS-422/485 (Interactive & Block modes). 15
RS-422/485 (Network mode) .........16
OIT Jumper ...................17
OIT Connection ................17
5-Wire RS-422/485 (Network mode) 18
3-Wire RS-422/485 (Network mode) 19
Network Termination ............19
Network Grounding.............20
CHAPTER 2: OIT Configuration ............21
Configuration Mode...................21
Operating Parameters .................24
OIT Display Brightness or Viewing Angle 24
Baud Rate .......................24
Parity...........................25
Data Bits ........................25
Stop Bits ........................25
Handshaking .....................26
Operating Mode ..................27
Line Terminator ...................27
Append Linefeed ..................28
Local Echo .......................29
Block Echo .......................29
Turn-Around Delay ................29
Delayed Linefeed..................30
Use 3-Wire RS-485 ................30
Network Address ..................31
Tab Width .......................31
Cursor Type ......................31
Wrap Around.....................32
Local Keyboard ...................32
Key Click ........................33
Local Setup ......................33
Passwords .......................33
Printer ..........................34
CHAPTER 3: Operating Modes .............35
Interactive Mode .....................35
Block Mode .........................36
Network Mode.......................37
CHAPTER 4: Using the OIT’s Display ........41
Extended Character Set ................41
Displaying Text from the OIT’s Keypad .....41
Displaying Text from the Host Controller . . . 43
Using a Display Variable ............43
Displaying Text from Predefined Messages . . 44
Optional Settings for Predefined Messages 45
CHAPTER 5: Using the OIT’s Function Keys ...47
General Features.....................47
Function Keys as Push-on/Push-off Switches . 49
Function Keys as Momentary Switches .....50
Disabling a Function Key ...............51
CHAPTER 6: LED and Printer Operation ......53
Using the OIT’s LEDs ..................53
Using a Serial Printer ..................53
APPENDIX A: Control Commands ..........A-1
Configuration Control Commands ........A-2
General Purpose Control Commands ......A-5
Display Control Commands .............A-8
APPENDIX B: Control Codes...............B-1
APPENDIX C: Extended Character Sets.......C-1
MAP460D, OIT3100 Series, OIT3600,
OIT4100 Series ......................C-1
MAP320D, OIT3200, OIT3250...........C-2
MAP340D, OIT4400, OIT4450...........C-3
OIT5400 ...........................C-4
APPENDIX D: Keyborad Layouts............D-1
APPENDIX E: Slide-in Legend Templates .....E-1
Blank Legends for Photocopying..........E-1
Dimensions for Computer Generated Legneds E-6
APPENDIX F: Troubleshooting .............F-1
INDEX
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any
form or by any means, electronic or mechanical, for any purpose, without the express written permission of Maple Systems, Inc.
© 1999 Maple Systems, Inc.
Microsoft and MS-DOS are registered trademarks, and Windows is a trademark of Microsoft Corporation.
Vedere la pagina 0
1 2 3 4 5 6 ... 92 93

Sommario

Pagina 1 - Table of Contents

Table of ContentsINTRODUCTION: Welcome ...iAbout Your Documentation ...iConventions ...iOIT Models Supported .

Pagina 2 - About Your Documentation

Configure a Momentary Function KeyMomentary function keys can be configured to repeat the predefined ASCII string while thefunction key is pressed. Th

Pagina 3 - Operational Overview

6. In Pos. 7:•double click Pos. 7 and the Non-Printable Characters dialog box appears•double-click {CR} to select CR and return to the Function Key AS

Pagina 4 - Getting Started

Downloading a STEPware-100 Project to Your OITConnect OIT to PC and Power SupplyGetting Started 91010-0096, Rev. 04OITCom2(Rear ofOIT)7431-00497431-00

Pagina 5 - STEPware-100 Tutorial

Place OIT in Download/Upload ModeNew OITNOTE:If using an OIT3160 or OIT4160, refer to the Existing OIT section below.NOTE:If using an OIT3165/4165, OI

Pagina 6 - Add Two Predefined Messages

3. Next, press the [ENTER] key to display the following message:OIT Model MessageOIT3100 and OIT4100 Series Password?All other models Enter Setup Pass

Pagina 7

To download a STEPware-100 project to the OIT:1. Start STEPware-100 and open your project.NOTE:The OIT must be in Download/Upload mode to accept a pro

Pagina 8 - 6. In Pos. 2, type n

Verifying Your OIT is OperationalConnect OIT to PC and Power SupplyGetting Started 131010-0096, Rev. 04OITCom2(Rear ofOIT)7431-00497431-0050APrinterOI

Pagina 9

Setup PC’s Terminal Emulation Program1. Start your terminal emulation program.2. Verify settings:Sample Communications SessionBefore executing this sa

Pagina 10

Connecting Your OIT to the Host ControllerThe information in this section is supplemental to the information in your OITInstallation Manual. Please re

Pagina 11 - 1010-0096, Rev. 04

5-Wire RS-422/485Host ControllerOIT Terminal Block(MAP460D, OIT3600)OIT Port 1(OIT3100 andOIT4100 Series)OIT Port 1(all other models)TXD+ Pin4—RXD+ Pi

Pagina 12 - Getting Started 9

INTRODUCTIONWelcomeWelcome to Maple Systems’ STEP1 Standard Terminal Emulation Protocol, a powerfulterminal emulation protocol for use with Maple Syst

Pagina 13

OIT JumperAll of the OITs, except the OIT3100 and OIT4100 Series, have a jumper that must bemoved when connecting the OIT to a network. Refer to the S

Pagina 14 - Transfer Project

5-Wire RS-422/485 (Network mode)18 STEP1 Protocol Operation Manual1010-0096, Rev. 045COMRXD+RXD-+24V3421TB1ShieldOITFrom or ToHost or OIT+24VGNDPower

Pagina 15

3-Wire RS-422/485 (Network mode)If you decide to use 3-wire RS-422/485, the following limitations apply:1. The host controller must disable or tri-sta

Pagina 16 - Getting Started 13

Network GroundingTo communicate properly, serious attention must be paid to the grounding scheme of thedevices connected to the com-link. Improper gro

Pagina 17 - Sample Communications Session

CHAPTER 2OIT ConfigurationYour OIT must be configured using the STEPware-100 configuration software before itcan communicate with your host controller

Pagina 18 - Getting Started 15

2. At Parameters?, press the OIT’s TOGGLE key to alternate between MODIFY andVIEW, then press the OIT’s ENTER key to accept and continue.Option Descri

Pagina 19 - NETWORK CABLE

5. The following Level 1 menus appear in order. If you select YES at a Level 1 menu,the corresponding Level 2 menus appear. If you select NO at a Leve

Pagina 20 - OIT Connection

Operating ParametersThe STEP1 protocol has many operating parameters which determine how the OITcommunicates to the host controller. These operating p

Pagina 21 - Host or OIT

Parity SettingThis parameter determines the parity that the OIT uses to communicate to the hostcontroller. Options are Even, Odd, None, Mark, Space. W

Pagina 22 - Power Supply

To modify this parameter in Configuration mode:1. At Stop Bits:, use the OIT’s TOGGLE key to select the desired number of stop bits.Refer to the Confi

Pagina 23 - MAP460D OIT3160

OIT Models SupportedThe STEP1 Protocol supports the following OIT models:Previous models, such as the MAP320B-240B or OIT3200-A00, are not supported.O

Pagina 24 - OIT Configuration

Hardware HandshakingHardware handshaking, which uses the CTS/RTS format, is available only in Interactiveand Block modes. The following rules apply:1.

Pagina 25

In all three modes, the line terminator is sent to the host controller when the OITresponds to a control command and when the OIT’s ENTER key is press

Pagina 26 - OIT Configuration 23

Local Echo SettingThis parameter determines whether local echo is used when the OIT is operating inInteractive mode. If enabled, each character sent t

Pagina 27 - Operating Parameters

To modify this parameter in Configuration mode:1. At Turn Delay:, use the OIT’s TOGGLE key to select the desired turnaround delay.Refer to the Configu

Pagina 28 - Stop Bits Setting

Network Address SettingThis parameter determines the network address used by the host controller tocommunicate with this OIT when in Network mode. Opt

Pagina 29 - Handshaking Setting

To modify this parameter from the host controller:1. Use the Display and Cursor Format Control control command. Refer to Appendix A:Control Commands f

Pagina 30 - Line Terminator Setting

Key Click SettingThis parameter determines whether an audible key click occurs whenever a key is pressedon the OIT’s keyboard.To modify this parameter

Pagina 31 - Append Linefeed Setting

To modify this parameter using STEPware-100:1. Open the Configuration Editor.2. In the OIT Operational Settings group box, choose the Editor button to

Pagina 32 - Turn-Around Delay Setting

CHAPTER 3Operating ModesYour OIT can be programmed to operate in one of three operating modes: Interactive,Block, or Network. These modes affect how t

Pagina 33 - Use 3-Wire RS-485 Setting

OIT Key Data Sent to Host Local Echo Mode OperationEnterLine Terminator(ETX, CR, LF,orCR/LF)If the line terminator isETX, this key has no affect.If th

Pagina 34 - Cursor Type Setting

CHAPTER 1Getting StartedThe Getting Started chapter walks you through all the steps required to setup your OIT:•What You Will Need•Installing STEPware

Pagina 35 - Local Keyboard Setting

OIT Key OperationDeleteDeletes the last character entered into the Keyboard Input Buffer, deletes thecharacter to the left of the cursor and moves the

Pagina 36 - Passwords Setting

When using Network mode, always follow these rules:1. Every OIT on the network must be assigned a unique network address.2. Every OIT on the network m

Pagina 37 - Printer Settings

Sample Network SessionBelow is a sample session showing a host controller communicating with three OITs on amultidrop network. The OITs have network a

Pagina 38 - Operating Modes

This page intentionally left blank.40 STEP1 Protocol Operation Manual1010-0096, Rev. 04

Pagina 39 - Block Mode

CHAPTER 4Using the OIT’s DisplayThe OIT displays data input from the OIT’s keypad, data sent from the host controller,and data stored in predefined me

Pagina 40 - Network Mode

•in Interactive mode, additional characters overwrite the character in the last column,unless the word-wrap feature is enabled. If word-wrap is enable

Pagina 41 - Network Addressing

OIT Key Interactive Mode Block & Network ModesFunction Keys& ScreenDependentFunction KeysDisplays the predefined ASCII stringor, if the Displa

Pagina 42 - Sample Network Session

on creating, writing to, and deleting display variables. Refer to Appendix A: ControlCommands and Appendix B: Control Codes for more information.To cr

Pagina 43

Notice that part of Message #25 has been truncated with the last character of the messagelocated in the last position of Line #2. Refer to Appendix A:

Pagina 44 - Using the OIT’s Display

This page intentionally left blank.46 STEP1 Protocol Operation Manual1010-0096, Rev. 04

Pagina 45

4. Type a:\setup (substitute b for a if your 3.5-inch drive is configured as the b drive).5. Choose the OK button.6. Follow the instructions on your s

Pagina 46 - Using a Display Variable

CHAPTER 5Using the OIT’s Function KeysThe OIT’s function keys provide the ability to create a predefined string of characterscalled ‘ASCII Strings’ th

Pagina 47

•ENTER key - this action allows the function key to behave as an ENTER key, enabling theOIT operator to send a line terminator to the host and perform

Pagina 48

Each state of the function key can be configured to send a predefined message to the OITscreen. This allows a different message to be displayed depend

Pagina 49

2. In the Assignment group box, select the appropriate option button.3. In the Action drop down list box, select Push On/Off.4. In the Key ON Message

Pagina 50 - Using the OIT’s Function Keys

6. Choose the Done button to return to the Function Key Editor dialog box.7. If you want to program a Key OFF Message, repeat steps 4 through 6 using

Pagina 51 - Function Key ASCII Strings

This page intentionally left blank.52 STEP1 Protocol Operation Manual1010-0096, Rev. 04

Pagina 52 - Send Message Immediately

CHAPTER 6LED and Printer OperationUsing the OIT’s LEDsSome of the OIT models which support the STEP1 protocol have LEDs which can beactivated by contr

Pagina 53

Refer to the OIT’s Installation Manual for information on wiring.Toconfigure your STEPware-100 project for use with your printer:1. Start STEPware-100

Pagina 54 - Disabling a Function Key

APPENDIX AControl CommandsControl commands are multiple ASCII characters, starting with the command initiator (ESCcontrol character) and ending with t

Pagina 55

ControlCharacterDecimalNotationHexadecimalNotationBASICCommandTerminal KeyboardKeypressesESC 27 1B CHR$(27) CTRL [STX 2 02 CHR$(2) CTRL BCR 13 0D CHR$

Pagina 56 - LED and Printer Operation

5. The Configuration Editor is used to specify the OIT’s operating parameters. Refer toChapter 2: OIT Configuration for more information. When finishe

Pagina 57

Request Configuration Data CommandESC c terminatorResponse: class version revision serial terminatorclass: 1 = OIT3160, 2 = OIT4160, 3 = OIT3600, 4 =

Pagina 58 - Control Commands

Set Turn-Around Delay CommandESC t delay terminatordelay: 0 = none,1=50milliseconds, 2 = 100 milliseconds, 3 = 250 millisecondsResponse: noneDescripti

Pagina 59

Set Line Terminator CommandESC T lineterminator terminatorline terminator:0=ETX,1=CR,2=LF,3=CR/LFResponse: noneDescription: Allows the host controller

Pagina 60 - Keyboard Control Command

Poll OIT Buffer CommandESC p terminatorResponse: contents terminatorcontents: OIT’s Keyboard Output Buffer contentsDescription: Allows the host contro

Pagina 61 - Set Operating Mode Command

Print Text CommandESC P text terminatortext: up to 40 ASCII characters (printable or control)Response: noneDescription: Allows the host controller to

Pagina 62 - Clear Output Buffer Command

Enable Block Mode CommandESC { start end fill terminatorstart: 00 to 39. Starting cursor column number. 00 defaults to the position ofthe cursor at th

Pagina 63 - Print Screen Command

Create Display Variable CommandESC w length terminatorlength: 1 to 40, defaults to 4 if not specifiedResponse: noneDescription: Allows the host contro

Pagina 64 - System LED Command

This page intentionally left blankA-10 STEP1 Protocol Operation Manual1010-0096, Rev. 04

Pagina 65 - Display Control Commands

APPENDIX BControl CodesControl codes are non-printable ASCII control characters sent from the host controller tothe OIT which cause the OIT to perform

Pagina 66 - Read Cursor Position Command

This page intentionally left blank.B-2 STEP1 Protocol Operation Manual1010-0096, Rev. 04

Pagina 67

6. Choose the Done button to return to the STEPware-100 main screen. The specialcharacter displayed in the text box next to the Add To List button dis

Pagina 68 - Control Codes

APPENDIX CExtended Character SetsThe following tables list the extended character set for each OIT model. If the OITreceives one of the listed ASCII C

Pagina 69

MAP320D, OIT3200, OIT3250C-2 STEP1 Protocol Operation Manual1010-0096, Rev. 04ExtendedCharacterASCIICode~ 126‚ 127ƒ 161„ 162… 163† 164‡ 165ˆ 166‰ 167Š

Pagina 70 - Extended Character Sets

MAP340D, OIT4400, OIT4450Appendix C: Extended Character Sets C-31010-0096, Rev. 04Ext. Char. Code~ 126‚ 127ƒ 128„ 129… 130† 131‡ 132ˆ 133‰ 134Š 135‹ 1

Pagina 71 - MAP320D, OIT3200, OIT3250

OIT5400C-4 STEP1 Protocol Operation Manual1010-0096, Rev. 04Ext. Char. Code~ 126‚ 128ƒ 129„ 130… 131† 132‡ 133ˆ 134‰ 135Š 136‹ 137Ext. Char. CodeŒ 138

Pagina 72 - MAP340D, OIT4400, OIT4450

APPENDIX DKeyboard Layouts:OIT3165/4165, OIT3175/4175 and OIT3185/4185The keyboards of the OIT3165/4165, OIT3175/4175 and OIT3185/4185 differ from the

Pagina 73

The keyboard that is created using the STEPware-100 configuration software becomesactive only afterthe OIT has finished it’s initialization routines w

Pagina 74 - Keyboard Layouts:

Appendix D: Slide-in Legends D-31010-0096, Rev. 047418529360CLEARENTERToggleOIT3175/41757418529360CLEARENTERToggleOIT3185/OIT4185

Pagina 75 - OIT3185/4185

This page intentionally left blank.D-4 STEP1 Protocol Operation Manual1010-0096, Rev. 04

Pagina 76 - OIT3185/OIT4185

APPENDIX ESlide-in Legend TemplatesSome of the OIT Family Operator Interface Terminals contain clear windows that allowyou to insert your own legends

Pagina 77

OIT3165A, OIT3185A, OIT4165A, and OIT4185A LegendOIT3175A and OIT4175A LegendE-2 STEP1 Protocol Operation Manual1010-0096, Rev. 04switch centerlines&q

Pagina 78 - Slide-in Legend Templates

4. In the Key ON Message group box, choose the Edit button to display the FunctionKey ASCII String Editor dialog box.5. In Pos. 1, type o.6. In Pos. 2

Pagina 79 - OIT3175A and OIT4175A Legend

OIT3200B and OIT3250B LegendsAppendix E: Keyboard Legends E-31010-0096, Rev. 04(Middle)(Left)13(Right)2Check Dimension: 4.00" [101.6 mm]"Ti

Pagina 80 - OIT3200B and OIT3250B Legends

OIT4400B and OIT4450B LegendsE-4 STEP1 Protocol Operation Manual1010-0096, Rev. 04Function Keys and Logo/Product ID"Tick" marks indicate edg

Pagina 81 - OIT4400B and OIT4450B Legends

OIT5400B LegendsAppendix E: Keyboard Legends E-51010-0096, Rev. 04"Tick marks" indicateedge of viewable area(LEFT)F41F3F2F1Check Dimension 4

Pagina 82 - OIT5400B Legends

Dimensions for Computer Generated LegendsThe dimensions on the following pages can be used to create legends using a computergraphics program.When cre

Pagina 83

OIT3165A, OIT3185A, OIT4165A, and OIT4185A LegendOIT3175A and OIT4175A LegendAppendix E: Keyboard Legends E-71010-0096, Rev. 041.70043,18][1,78]0.0700

Pagina 84

OIT3200B and OIT3250B LegendsE-8 STEP1 Protocol Operation Manual1010-0096, Rev. 041.12(F8)(Middle)0.50(Left)0.10 [2.5]1(F4)3(F12)(Right)20.57(F5)(F6)(

Pagina 85 - Logo/Product ID

OIT4400B and OIT4450B LegendsAppendix E: Keyboard Legends E-91010-0096, Rev. 04(S1) (S2) (S3) (S6)(S4) (S5) (S7) (S8)0[1.5][14.2][28.2][42.2][56.1][70

Pagina 86 - Status LEDs: OIT4450B Only

OIT5400B LegendsE-10 STEP1 Protocol Operation Manual1010-0096, Rev. 041.18(F8)0.10 [2.5](F4)(F16)0.63(F5)(F6)(F7)(F3)(F2)(F1)Chamfer 0.060 x 0.060[1.5

Pagina 87 - Status LEDs

APPENDIX FTroubleshooting“System DLL’s Missing or Corrupt” Message Displays DuringSTEPware-100 InstallationThe “System DLL’s Missing or Corrupt” messa

Pagina 88 - Troubleshooting

•for OIT3165/4165, OIT3175/4175 and OIT3185/4185 models:1. While pressing and holding down the CLEAR or ENTER key, cycle power to theOIT. Continue pre

Pagina 89

7. In Pos. 3:•choose the Non-Printable button and the Non-Printable Characters dialog box appears•select {CR}•then choose the Done button to return to

Pagina 90

3. Press the F1 key.4. Press the F4 key.5. Press the F7 key.6. Wait for a few seconds. The OIT will reinitialize, allowing you to enter LocalSetup by

Pagina 91

This page intentionally left blankF-4 STEP1 Protocol Operation Manual1010-0096, Rev. 04

Pagina 92 - 1010-0096, Rev 04

Index1010-0096, Rev 04Index!3-Wire RS-485 30Interactive & Block modes 15Limitations 19Network mode 195-Wire RS-485Interactive & Block modes 15

Pagina 93

STEP1 Protocol Operation Manual1010-0096, Rev 04EExtended Character Sets 41, C-1Inserting into a Predefined Message 41MAP320D, OIT3200, OIT3250 C-2MAP

Commenti su questo manuale