1010-1017 Rev. 00 12
Ethernet
To connect your OMI to your computer via the10/100 Base-T Ethernet
port requires a standard Ethernet crossover cable (Maple P/N 7431-
0104). If you use a switch or router between the computer and the OMI,
use a straight-thru cable (Maple P/N 7431-0103).
Once a connection is made, you will need to install a data
synchronization program use as Microsoft's ActiveSync onto your
computer. ActiveSync provides the ability to manually transfer files to
the OMI5000 or download application software. ActiveSync is available
from Microsoft's support website for mobile applications.
Maintenance
Figure 6: DIP switch positions (power must be cycled on the OMI to enable the DIP
switch mode).
Touchscreen Calibration mode
Force into Boot Loader mode
Touchscreen Calibration mode: This mode allows you to recalibrate
the touchscreen.
Boot Loader mode: This mode forces the OMI to not execute the
project. This mode is used when replacing or reinstalling the operating
system. Contact Maple Systems for more information.
Normal Operation: All DIP switches must be in the OFF position for
normal operation.